PERBANDINGAN TINGKAT AKURASI DAN PRESISI KADAR KESADAHAN TOTAL DALAM AIR METODE KOMPLEKSOMETRI DENGAN PENAMBAHAN AQUADEST YANG BERVARIASI

Detail Cantuman

CD-ROM

PERBANDINGAN TINGKAT AKURASI DAN PRESISI KADAR KESADAHAN TOTAL DALAM AIR METODE KOMPLEKSOMETRI DENGAN PENAMBAHAN AQUADEST YANG BERVARIASI

XML

ABSTRAK




PERBANDINGAN TINGKAT AKURASI DAN PRESISI KADAR KESADAHAN TOTAL DALAM AIR METODE KOMPLEKSOMETRI DENGAN PENAMBAHAN AQUADEST YANG BERVARIASI

Penulis : Muhamad Tommy Julianoor Pembimbing : Haitami, Akhmad Muntaha

Kesadahan total merupakan salah satu parameter kimia sebagai penentu kualitas air bersih. Penetapan kadar kesdahan total umumnya menggunakan metode SNI 06.6989.12-2004 dengan pengenceran aquadest sebanyak 25 ml. Penelitian ini dilakukan untuk mengetahui perbedaan akurasi dan presisi kadar kesadahan total dalam air dengan penambahan aquadest 25 ml, 50 ml, dan 100 ml. Akurasi adalah ukuran suatu nilai yang berdekatan dengan nilai sebenarnya dan dinyatakan sebagai persen recovery (%R). Presisi adalah ukuran yang menunjukkan kedekatan nilai hasil suatu pengukuran yang dilakukan secara berulang dan diukur sebagai simpangan baku atau simpangan baku relatif (koefisien variasi/%RSD). Jenis penelitian ini adalah true experimental dengan posttest-only control group design. Hasil uji akurasi penambahan aquadest 25 ml berada pada 92.72 – 104.67 % yang menunjukkan bahwa nilai tersebut memenuhi kriteria (% recovery = 85-115). Sedangkan, hasil uji akurasi dengan penambahan aquadest 50 ml dan 100 ml masing-masing berada pada 66 – 72.00 % dan 52.40 – 53.00 %, yang menunjukkan bahwa nilai tersebut tidak memenuhi kriteria. Hasil uji presisi penambahan aquadest 25 ml, 50 ml, dan 100 ml pada rentang %RSD 1.54-5.56 < 8% (CV Horwitz) yang menunjukkan nilai tersebut memenuhi kriteria. Data hasil penelitian dianalisis menggunakan uji statistika repeated measure anova dengan tingkat kepercayaan 95%. Terdapat perbedaan hasil uji akurasi yang dinyatakan dengan nilai sig. sphericity assumed 0.001 < 0.05 (alpha). Tidak ada perbedaan hasil uji presisi yang dinyatakan dengan nilai sig. sphericity assumed 0.144 > 0.05 (alpha). Disarankan melakukan penambahan aquadest sebesar 25 ml dalam melakukan pengujian kesadahan total. Hal ini dikarenakan metode tersebut memiliki validitas yang baik. Kata kunci : Akurasi, Presisi, Kesadahan Total

ABSTRACK

COMPARISON OF ACCURACY AND PRECISION LEVELS OF TOTAL HUMIDITY LEVELS IN WATER COMPLEXION METHODS WITH THE ADDITION OF VARIED AQUADESTS

Author : Muhamad Tommy Julianoor Mentor : Haitami, Akhmad Muntaha Total hardness is one of the chemical parameters as a determinant of clean water quality. Determination of total kesdahan levels generally uses the SNI 06.6989.12-2004 method using 25 ml of distilled water. This research was conducted to determine the differences in accuracy and precision of total hardness levels in water with the addition of aquadest to 25 ml, 50 ml and 100 ml. Accuracy is the measure of a value that is close to the true value and is expressed as a percent recovery (% R). Precision is a measure that shows the closeness of the value of the results of a measurement carried out repeatedly and measured as a standard deviation or relative standard deviation (coefficient of variation /% RSD). This type of research is true experimental with posttest-only control group design. The results of the accuracy test of adding 25 ml aquadest are in the range of values 92.72 - 104.67% which shows that this value meets the criteria (% recovery = 85-115). Meanwhile, the accuracy of the test results with the addition aquadest of 50 ml and 100 ml respectively in the range of values 66 - 72.00% and 52.40 - 53.00%, which indicates that this value does not meet the criteria. The precision test results of adding 25 ml, 50 ml, and 100 ml aquadest in the range of % RSD values 1.54-5.56 < 8% (CV Horwitz) which indicate this value meets the criteria. Data were analyzed using the repeated measure ANOVA statistical test with a confidence level of 95%. There is a difference in the accuracy of the test results expressed by the value of sig. sphericity assumed 0.001 < 0.05 (alpha). There is no difference in the precision test results expressed by the value of sig. sphericity assumed 0.144 > 0.05 (alpha). It is recommended to add aquadest by 25 ml in total hardness testing. This is because the method has good validity.

Keywords: Accuracy, Precision, Total Hardness


Detail Information

Item Type
Penulis
Muhamad Tommy Julianoor - Personal Name
Haitami, - Personal Name
H. Akhmad Muntaha, S.Pd., MM - Personal Name
Student ID
Dosen Pembimbing
Penguji
Kode Prodi PDDIKTI
Edisi
Departement
Kontributor
Bahasa
Indonesia
Penerbit Jurusan Analis Kesehatan : Banjarbaru.,
Edisi
Subyek
No Panggil
ANK- 29/SKP-2020
Copyright
Doi

Lampiran Berkas

LOADING LIST...



Informasi


DETAIL CANTUMAN


Kembali ke sebelumnya  XML Detail