ABSTRAK
Perbandingan Penunndaan Pemeriksaan Darah Terhadap Hitung Jumlah Leukosit Menggunakan Hematology Analyzer
Penulis : Siti Rahmatul Janah Pembimbing : Wahdah Norsiah, Erfan Roebiakto
Pemeriksaan jumlah sel leukosit dapat menggunakan darah kapiler maupun darah vena dengan antikoagulan EDTA. Pemeriksaan darah EDTA sebaiknya segera dilakukan, bila terpaksa ditunda harus memperhatikan batas waktu penyimpanan. Hal yang tidak bisa dihindarkan karena jumlah dan macam pemeriksaan yang sangat banyak dan keterbatasan jumlah petugas sehingga pemeriksaan jumlah sel leukosit tertunda. Tujuan penelitian ini untuk mengetahui perbandingan penundaan pemeriksaan darah terhadap nilai hitung jumlah leukosit dengan menggunakan Hematology Analyzer. Jenis penelitian ini adalah Quasi Ekperimen dengan pendekatan One Group Pretest-Posttest Design. Penelitian dilakukan di laboratorium Analis Kesehatan Poltekkes Banjarmasin dengan jumlah responden 10 orang dengan 4 perlakuan sehingga didapat 40 sampel. Uji yang digunakan adalah Reapeted Anova dengan taraf signifikansi 95%,. Hasil penelitian pada sampel darah vena sebelum dilakukan penundaan adalah 6.555/mm3, kemudian mengalami penurunan setelah ditunda 1 jam 6.224/mm3 (5,04%); ditunda 2 jam 5.799/mm3 (11,53%) dan ditunda 3 jam 5.263/mm3 (19,71%), dari hasil uji didapatkan nilai signifikansi yaitu 0,000 (p<0,05) yang berarti terdapat perbedaan antara hitung jumlah leukosit sebelum dan setelah ditunda 1 jam, 2 jam dan 3 jam. Disarankan agar peneliti selanjutnya untuk melihat perubahan pada masing-masing jenis leukosit dengan metode manual atau melakukan penundaan pemeriksaan darah EDTA terhadap pasien leukositosis.
Kata kunci : Leukosit, Penundaan, darah EDTA

Comparison of Delays in Blood Checking to Count the Number of Leukocytes Using a Hematology Analyzer
Author: Siti Rahmatul Janah Advisor: Wahdah Norsiah, Erfan Roebiakto
Examination of leukocyte cells number can use capillary blood as well as venous blood with EDTA anticoagulants. EDTA blood examination should be done immediately, if forced to delayed should pay attention to the storage time limit. This is inevitable because of the number and variety of examination and the limited number of officers until the examination of the number of leukocyte cells is delayed. The purpose of this study to know the delay comparison of blood examination to the count value of leukocyte number by using Hematology Analyzer. The type of this study is Quasi Eksperimet With One Group Pretest-Posttest Design approach. The study was conducted in the laboratory of Health Analyst Poltekkes Banjarmasin with the number of respondents 10 people with 4 treatments until 40 samples were obtained. The test used was Reapeted Anova with 95% significance level. The results of the study on venous blood samples before delay were 6,555/mm3, then decreased after delay of 1 hour 6.224/mm3 (5.04%); delayed 2 hours 5.799/mm3 (11.53%) and delayed 3 hours 5.263/mm3 (19.71%), from the test results has obtained a significance value is 0.000 (p <0.05) which means there is a difference between the count of leukocyte number before and after delayed 1 hour, 2 hours and 3 hours. It is recommended to the next researcher to look at the changes in each leukocyte type by manual method or delay EDTA blood test for medical leukocytosis patients.
Keywords: Leukocyte, Delay, EDTA blood


Detail Information

Item Type
Penulis
Siti Rahmatul Janah - Personal Name
Wahdah Norsiah - Personal Name
Erfan Roebiakto, S.KM.,MS - Personal Name
Jujuk Anton Cahyono, M.Sc - Personal Name
Student ID
Dosen Pembimbing
Penguji
Kode Prodi PDDIKTI
Edisi
Departement
Kontributor
Bahasa
Indonesia
Penerbit Jurusan Analis Kesehatan : Banjarbaru.,
Edisi
Subyek
No Panggil
ANK- 11/SKP-2017
Copyright
Doi

Lampiran Berkas

LOADING LIST...



Informasi


DETAIL CANTUMAN


Kembali ke sebelumnya  XML Detail