EFEKTIFITAS SISTEM RBC ( ROTATING BIOLOGICAL CONTACTOR ) PADA IPAL PEKAPURAN RAYA PD.PAL BANJARMASIN TERHADAP PENURUNAN KADAR BOD (Biological Oxygen Demand) TAHUN 2017

Detail Cantuman

CD-ROM

EFEKTIFITAS SISTEM RBC ( ROTATING BIOLOGICAL CONTACTOR ) PADA IPAL PEKAPURAN RAYA PD.PAL BANJARMASIN TERHADAP PENURUNAN KADAR BOD (Biological Oxygen Demand) TAHUN 2017

XML

KEMENKES REPUBLIK INDONESIA
POLITEKNIK KESEHATAN BANJARMASIN
PROGRAM STUDI DIPLOMA IV
KESEHATAN LINGKUNGAN
TAHUN 2017

ABSTRAK
SKRIPSI

FIDYAN HIFZHANI
EFEKTIFITAS SISTEM RBC ( ROTATING BIOLOGICAL CONTACTOR ) PADA IPAL PEKAPURAN RAYA PD PAL BANJARMASIN TERHADAP PENURUNAN KADAR BOD (Biological Oxygen Demand) TAHUN 2017 (Syarifudin A, S.KM, M.S dan Arifin, S.KM, M) xiii + 82 Halaman; 14 Tabel; 5 Gambar; 5 Lampiran

Meningkatnya aktivitas manusia di rumah tangga menyebabkan semakin besarnya volume limbah yang dihasilkan dari waktu ke waktu. Volume limbah rumah tangga meningkat 5 juta m3 pertahun. PD PAL Kota Banjarmasin adalah perusahaan daerah pengelola air limbah kota Banjarmasin yang melakukan pengolahan air limbah sektor domestik (tinja) kota Banjarmasin. Teknologi pengolahan limbah yang diterapkan pada IPAL Kota Banjarmasin adalah sistem RBC.
Penelitian ini bertujuan untuk mengetahui efektivitas sistem RBC pada PD PAL Banjarmasin terhadap penurunan kadar BOD (Biological Oxygen Demand). Jenis penelitian ini bersifat analitik. Desain penelitian yang digunakan adalah one group pretest posttest design. Tempat pelaksanaan penelitian dilakukan di IPAL Pekapuran Raya PD PAL Kota Banjarmasin Tahun 2017. Populasi penelitian adalah limbah cair dari pipa inlet dan outlet. Sampel adalah air limbah yang diambil dalam bak penampung pipa inlet dan outlet.
Hasil penelitian menunjukan Kadar BOD (Biological Oxygen Demand) pada sampel air limbah sebelum diolah 130,97 mg/l, 116,98 mg/l, dan 193,45 mg/l. Sesudah dilakukan pengolahan 13,81 mg/l, 20,138 mg/l, dan 30,216 mg/l. Efektifitas RBC terhadap penurunan kadar BOD (Biological Oxygen Demand) pada IPAL Pekapuran Raya PD PAL kota Banjarmasin adalah dengan rata-rata 89,37% untuk hari pertama, 80,51% untuk hari kedua, dan 83,73% untuk hari ketiga. Terdapat perbedaan kadar BOD (Biological Oxygen Demand) sebelum dan sesudah diolah dengan RBC pada IPAL Pekapuran Raya PD PAL kota Banjarmasin.
Disarankan kepada pihak IPAL Pekapuran Raya Kota Banjarmasin untuk selalu mempertahankan pengolahan limbah cair yang sudah ada dan selalu perhatikan kinerja dari sistem RBC dengan cara memperhatikan masalah/gangguan yang terjadi di dalam proses RBC.

Kata kunci :IPAL, Sistem RBC, BOD
Kepustakaan : 19 (1983-2016)

THE MINISTRY OF HEALTH OF THE REPUBLIC OF INDONESIA
HEALTH POLYTECHNIC BANJARMASIN
DIPLOMA IV STUDY PROGRAMME
ENVIRONMENTAL HEALTH
2017
ABSTRACT
ESSAY

FIDYAN HIFZHANI
EFFECTIVENESS OF RBC (ROTATING BIOLOGICAL CONTACTOR) SYSTEM ON WWTP (WASTEWATER TREATMENT PLANT) PEKAPURAN RAYA WT (WASTEWATER TREATMENT) LOCAL COMPANY BANJARMASIN TO REDUCE BOD (BIOLOGICAL OXYGEN DEMAND) CONTENTS 2017 (Syarifudin A, S.KM, M.S dan Arifin, S.KM, M) xiii+ 82 Pages; 14 Tables; 5 Images; 5 Appendices

Increased household activities lead to increase the volume of waste generated over time. Annually, the household waste volume increases 5 million m3. WT Local Company Banjarmasin is a wastewater management company that performs domestic sewage treatment (feces) Banjarmasin city. Application of waste treatment technology on WWTP Banjarmasin is RBC system.
This study aimed to determine the effectiveness of RBC system on WT Local Company Banjarmasin to reduce BOD (Biological Oxygen Demand). This type of study was analytic. The study design used one group pretest posttest design. The place of study was WWTP Pekapuran Raya WT Local Company Banjarmasin 2017. The study population was wastewater from inlet and outlet pipes. Sample was wastewater taken inlet and outlet pipe tanks.
The result showed BOD (Biological Oxygen Demand) contents in the wastewater sample before it was processed of 130.97 mg/L, 116.98 mg/L, and 193.45 mg/l. After it was processed of 13.81 mg/L, 20.138 mg/L, and 30.216 mg/L. The effectiveness of RBC system on the reduce of BOD (Biological Oxygen Demand) in WWTP Pekapuran Raya WT Local Company Banjarmasin was 89.37% for first day, 80.51% for second day and 83.73% for the third day. There were differences before and after BOD (Biological Oxygen Demand) treated by RBC in WWTP Pekapuran Raya WT Local Company Banjarmasin
It is suggested to WWTP Pekapuran Raya Banjarmasin always maintain the existing liquid waste treatment and always aware to RBC system performance by considering the problems/disturbances occur in the RBC process.

Keywords : WWTP, RBC system, BOD
Literatute : 19 (1983-2016)


Detail Information

Item Type
Penulis
FIDYAN HIFZHANI - Personal Name
Syarifudin A., S.KM, MS - Personal Name
ARIFIN, S.KM.M.Kes - Personal Name
Student ID
Dosen Pembimbing
Penguji
Kode Prodi PDDIKTI
Edisi
Departement
Kontributor
Bahasa
Indonesia
Penerbit Jurusan kesehatan lingkungan : Banjarbaru.,
Edisi
Subyek
No Panggil
KL.03/SKP.2017
Copyright
Doi

Lampiran Berkas

LOADING LIST...



Informasi


DETAIL CANTUMAN


Kembali ke sebelumnya  XML Detail