Akurasi Waktu Sentrifugasi Hematokrit Modifikasi Metode Mikro Menggunakan Sentrfius Hettic EBA 3S

Detail Cantuman

CD-ROM

Akurasi Waktu Sentrifugasi Hematokrit Modifikasi Metode Mikro Menggunakan Sentrfius Hettic EBA 3S

XML

ABSTRAK

Akurasi Waktu Sentrifugasi Hematokrit Modifikasi Metode Mikro Menggunakan Sentrfius Hettic EBA 3S

Penulis : Ahmad Muttaqien Pembimbing : Ahmad Muhlisin; Wahdah Norsiah
Pemeriksaan hematokrit di beberapa pusat pelayanan kesehatan dan laboratorium kecil masih menggunakan metode manual dan ada yang melakukan modifikasi pemeriksaan hematokrit. Penelitian ini untuk Mengetahui akurasi waktu sentrifugasi hematokrit modifikasi metode mikro hematokrit menggunakan sentrifus Hettic EBA 3S yang mendekati dengan nilai hematokrit menggunakan mikro hematokrit HT 24 kecepatan 16.000 rpm selama 5 menit. Jenis penelitian ini adalah quasi eksperiment dengan rancangan penelitian postestt only control group design. Penelitian ini menggunakan 4 sampel dengan 6 perlakuan yang berbeda, sentrifugasi dengan sentrifus HT 24 16.000 rpm selama 5 menit, sentrifugasi dengan sentrifus Hettic EBA 3S 4.000 rpm selama 6, 9, 12, 15 dan 18 menit. Hasil data yang didapat di uji menggunakan Repeated Anova dari data tersebut di dapatkan hasil bahwa pada waktu sentrifugasi 6 menit ada perbedaan bermakna dan pada waktu sentrifugasi 9, 12, 15 dan 18 menit tidak ada perbedaan bermakna, untuk akurasi di dapatkan bahwa waktu sentrifugasi 15 menit memiliki akurasi yang tinggi sebesar 0,29 %. berdasarkan hasil tersebut, disimpulkan bahwa sentrifus Hettic EBA 3S dapat digunakan untuk pemeriksaan hematokrit modifikasi metode mikro. disarankan untuk peneliti selanjutnya menggunakan sampel darah yang beragam.

Kata Kunci : Hematokrit, sentrifus Hettic EBA 3S, Modifikasi Metode Mikro

ABSTRACT

Accuracy Of Micro Method Modified Hematocrit Centrifugation Using Sentrfius Hettic EBA 3S

Author : Ahmad Muttaqien Mentor : Ahmad Muhlisin; Wahdah Norsiah

Hematocrit examination in several health care centers and small laboratories still uses manual methods and there are those who modify hematocrit examinations. This study was to determine the time accuracy of modified hematocrit centrifugation of the micro-hematocrit method using a Hettic EBA 3S centrifuge which approached the hematocrit value using micro hematocrit HT 24 at 16,000 rpm for 5 minutes. This type of research is a quasi-experimental posttest only control group design. This study used 4 samples with 6 different treatments, centrifuging with HT 24 centrifuge 16,000 rpm for 5 minutes, centrifugation with a 3S 4,000 rpm Hettic EBA centrifuge for 6, 9, 12, 15 and 18 minutes. The results of the data obtained using Repeated Anova from the data obtained results that at 6 minutes centrifugation there were significant differences and at the time of centrifugation 9, 12, 15 and 18 minutes there was no significant difference, for accuracy to get that 15 minutes centrifugation time has a high accuracy of 0.29%. Based on these results, it was concluded that the Hettic EBA 3S centrifuge can be used for the hematocrit examination of modified micro methods. It is recommended for future researchers to use diverse blood samples.

Keywords: Hematocrit, 3S Hettic EBA centrifuge, Micro Method Modification


Detail Information

Item Type
Penulis
Ahmad Muttaqien - Personal Name
Ahmad Muhlisin - Personal Name
Wahdah Norsiah - Personal Name
Student ID
Dosen Pembimbing
Penguji
Kode Prodi PDDIKTI
Edisi
Departement
Kontributor
Bahasa
Indonesia
Penerbit Jurusan Analis Kesehatan : Banjarbaru.,
Edisi
Subyek
No Panggil
ANK- 04 SKP 2019
Copyright
Doi

Lampiran Berkas

LOADING LIST...



Informasi


DETAIL CANTUMAN


Kembali ke sebelumnya  XML Detail