“The Effect of Plate Count Medium Volume Variations for the Results of Bacterial Colony Counting on Total Plate Count Examination”
XMLABSTRACT
“The Effect of Plate Count Medium Volume Variations for the Results of
Bacterial Colony Counting on Total Plate Count Examination”
Author: Dita Irianti Rukmana
Adviser: Ratih Dewi Dwiyanti, Aima Insana
Total Plate Count (TPC) is used to determine the number of microorganisms, both
bacteria and fungi. TPC pouring method often done by pouring Plate Count Agar
(PCA) medium directly without measuring volume. FDA recommends pouring
media ranging from 12-15 ml per petridish while SNI 2897:2008 recommends 15-
20 ml. This research aims to find out the effect of PCA volume variations (10 ml,
12 ml, 14 ml, 16 ml, 18 ml and 20 ml) to the results of Escherichia coli bacterial
colonies counting on the TPC examination. This is true-experimental design’s
research with Posttest only control design. Repetition is done by 5X for each control
group (20 ml PCA) and the test group (10 ml, 12 ml, 14 ml, 16 ml, 18 ml PCA) then
counting the number of bacterial colonies grew. The average number of colonies
from test group are 92 CFU/ml, 88 CFU/ml, 92 CFU/ml, 97 CFU/ml, 92 CFU/ml;
and the control group is 93 CFU/ml. Mean difference between the test group and
the control group was 1,07 – 4,28 %. Repeated ANOVA test sig. (Greenhouse-
Geisser) 0.368 ≥ 0.05. H0 was accepted, there was no difference in the colony count
results on the TPC examination with 10 ml, 12 ml, 14 ml, 16 ml, 18 ml and 20 ml
PCA media volume. It was concluded that there is no effect of PCA volume
variations on the results of Escherichia coli colony counting in TPC examination.
It is recommended to pour 10-20 ml of PCA/petridish and better distributed in tubes.
Keywords: Total Plate Count, Plate Count Agar, Medium Volume
viii
ABSTRAK
“Pengaruh Variasi Volume Media Plate Count Agar terhadap Hasil
Perhitungan Koloni Bakteri pada Pemeriksaan Angka Lempeng Total”
Penulis: Dita Irianti Rukmana
Pembimbing: Ratih Dewi Dwiyanti, Aima Insana
Angka Lempeng Total (ALT) digunakan untuk menentukan jumlah
mikroorganisme baik bakteri maupun jamur. ALT metode tuang seringkali
dilakukan dengan menuang langsung Plate Count Agar (PCA) ke cawan tanpa
pengukuran volume. FDA merekomendasikan penuangan media berkisar 12-15 ml
per cawan sementara SNI 2897:2008 menyarankan sebanyak 15-20 ml. Penelitian
ini bertujuan mengetahui pengaruh variasi volume media PCA (10 ml, 12 ml, 14
ml, 16 ml, 18 ml dan 20 ml) terhadap hasil perhitungan koloni bakteri Escherichia
coli pada pemeriksaan Angka Lempeng Total. Jenis penelitian true-eksperimental
design dengan Posttest only control design. Pengulangan dilakukan 5X terhadap
masing-masing kelompok kontrol (PCA 20 ml) dan kelompok uji (PCA 10 ml, 12
ml, 14 ml, 16 ml, 18 ml) lalu dihitung jumlah koloni bakteri yang tumbuh. Rata-
rata jumlah koloni dari variasi volume PCA kelompok uji secara berurutan adalah
92 CFU/ml, 88 CFU/ml, 92 CFU/ml, 97 CFU/ml, 92 CFU/ml; dan pada kelompok
kontrol sebesar 93 CFU/ml. Selisih rata-rata kelompok uji dibandingkan dengan
kelompok kontrol adalah 1,07 - 4,28%. Uji Repeated Anova menunjukkan sig.
(Greenhouse-Geisser) 0,368 ≥ 0.05. H0 diterima, artinya tidak ada perbedaan hasil
perhitungan koloni pada pemeriksaan ALT yang diperiksa dengan volume media
PCA 10 ml, 12 ml, 14 ml, 16 ml, 18 ml dan 20 ml. Dapat disimpulkan tidak ada
pengaruh variasi volume media PCA (10 ml, 12 ml, 14 ml, 16 ml, 18 ml dan 20 ml)
terhadap hasil perhitungan koloni bakteri Escherichia coli pada pemeriksaan ALT
dan disarankan untuk menuangkan media PCA 10-20 ml per cawan dan sebaiknya
telah didistribusikan dalam tabung-tabung.
Kata Kunci: Angka Lempeng Total, Plate Count Agar, Volume Media
Detail Information
Item Type | |
---|---|
Penulis | |
Student ID | |
Dosen Pembimbing | |
Penguji | |
Kode Prodi PDDIKTI | |
Edisi | |
Departement | |
Kontributor | |
Bahasa |
Indonesia
|
Penerbit | Jurusan Analis Kesehatan : Banjarbaru., 2024 |
Edisi | |
Subyek | |
No Panggil |
SKP RPL 007R TLM/ 2024
|
Copyright | |
Doi |