PERBANDINGAN HASIL GLUKOSA DARAH POCT (Oksidase) DENGAN POCT (Dehidrogenase) TERHADAP SPEKTROFOTOMETER DI LABORATARIUM RSUD DATU SANGGUL RANTAU

Detail Cantuman

CD-ROM

PERBANDINGAN HASIL GLUKOSA DARAH POCT (Oksidase) DENGAN POCT (Dehidrogenase) TERHADAP SPEKTROFOTOMETER DI LABORATARIUM RSUD DATU SANGGUL RANTAU

XML

ABSTRAK
PERBANDINGAN HASIL GLUKOSA DARAH POCT (Oksidase) DENGAN
POCT (Dehidrogenase) TERHADAP SPEKTROFOTOMETER DI
LABORATARIUM RSUD DATU SANGGUL RANTAU
Penulis : Farida Noer Laily
Pembimbing : Jujuk Anton Cahyono, Erfan Roebiakto
Pemeriksaan glukosa darah dapat dilakukan dengan beberapa metode.
Metode GOD PAP merupakan metode yang paling sering digunakan di Indonesia.
Metode GOD PAP menggunakan spektrofotometer dapat dijadikan rujukan untuk
pemeriksaan glukosa darah. Metode GOD PAP sudah terstandarisasi dengan baik
sehingga memiliki ketelitian dan akurasi yang baik, namun metode ini
memerlukan jumlah sampel yang banyak dan waktu pemeriksaan yang lama.
Alternatif pemeriksaan glukosa darah cepat, mudah dan memerlukan sedikit
sampel ialah dengan POCT. Berdasarkan enzim yang digunakan, POCT terbagi 2
yaitu POCT (Oksidase) dan POCT (Dehidrogenase). Pemeriksaan glukosa darah
dengan POCT belum terstandarisasi dengan baik sehingga hasil glukosa darah
POCT perlu dibandingkan secara berkala dengan metode rujukan. Penelitian ini
bertujuan untuk mengetahui perbandingan hasil glukosa darah POCT (Oksidase),
POCT (Dehidrogenase) dan GOD PAP. Penelitian ini dilakukan di Laboratorium
RSUD Datu Sanggul Rantau pada bulan Juli 2022. Jenis penelitian observasi
analitik dengan rancangan studi komparatif. Sampel pada penelitian berjumlah 30
dan diambil secara purposive sampling. Hasil glukosa darah POCT (Oksidase)
adalah 72-111 mg/dl dengan rata-rata 95,87 mg/dl, hasil glukosa darah POCT
(Dehidrogenase) adalah 79 – 115 mg/dl dengan rata-rata 101,97 mg/dl dan hasil
glukosa darah GOD PAP adalah 75 – 114 mg/dl dengan rata-rata 99,53 mg/dl.
Berdasarkan hasil Uji Repeated Anova didapatkan nilai signifikansi < 0,05 yang
berarti dapat disimpulkan bahwa terdapat perbedaan bermakna antara POCT
(Oksidase), POCT (Dehidrogenase) dan GOD PAP (metode rujukan), sehingga
dalam penggunaan POCT sangat penting untuk selalu memperhatikan petunjuk
dari kit insert masing-masing alat dan secara rutin melakukan kalibrasi, kontrol
dan membandingkan hasil POCT dengan metode rujukan (spektrofotometer).
Penelitian ini hanya dilakukan pada kadar glukosa darah normal sehingga perlu
penelitian lebih lanjut untuk kadar glukosa darah yang rendah atau tinggi.
Kata Kunci: Glukosa darah, POCT (Oksidase), POCT (Dehidrogenase)
ABSTRACT
COMPARISON OF RESULTS OF POCT (Oxidase) BLOOD GLUCOSE WITH
POCT (Dehydrogenase) AGAINST SPECTROPHOTOMETER IN
LABORATARIUM OF DATU SANGGUL RANTAU HOSPITAL
Author : Farida Noer Laily
Advisers : Jujuk Anton Cahyono, Erfan Roebiakto
Checking blood glucose can be done by several methods. The GOD PAP
method is the most frequently used method in Indonesia. The GOD PAP method
using a spectrophotometer can be used as a reference for blood glucose
examination. The GOD PAP method is well standardized so it has good precision
and accuracy, but this method requires a large number of samples and a long
inspection time. An alternative to checking blood glucose quickly, easily and
requiring a small sample is POCT. Based on the enzymes used, POCT is divided
into 2, namely POCT (Oxidase) and POCT (Dehydrogenase). Examination of blood
glucose by POCT has not been well standardized so that POCT blood glucose
results need to be compared periodically with the reference method. This study aims
to compare the blood glucose results of POCT (Oxidase), POCT (Dehydrogenase)
and GOD PAP. This research was conducted at the Laboratory of Datu Sanggul
Rantau Hospital in July 2022. This type of research is analytic observation with a
comparative study design. The sample in this study was 30 and taken by purposive
sampling. POCT (Oxidase) blood glucose results were 72-111 mg/dl with an
average of 95.87 mg/dl, POCT (Dehydrogenase) blood glucose results were 79 –
115 mg/dl with an average of 101.97 mg/dl and GOD PAP blood glucose results
were 75 – 114 mg/dl with an average of 99.53 mg/dl. Based on the results of the
Repeated Anova Test, a significance value of <0.05 was obtained, which means
that it can be concluded that there are significant differences between POCT
(Oxidase), POCT (Dehydrogenase) and GOD PAP (reference method), so that
when using POCT it is very important to always pay attention to the instructions
from the insert kit for each tool and carefully. Routinely calibrate, control and
compare POCT results with the reference method (spectrophotometer). This study
was only conducted at normal blood glucose levels, so further research is needed
for low or high blood glucose levels.
Keywords: Blood glucose, POCT (Oxidase), POCT (Dehydrogenase)


Detail Information

Item Type
Penulis
Farida Noer Laily - Personal Name
Jujuk Anton Cahyono, M.Sc - Personal Name
Erfan Roebiakto, S.KM.,MS - Personal Name
Dra. Anny Thuraidah, Apt.,MS. - Personal Name
Student ID
Dosen Pembimbing
Penguji
Kode Prodi PDDIKTI
Edisi
Departement
Kontributor
Bahasa
Indonesia
Penerbit Jurusan Analis Kesehatan : Banjarbaru.,
Edisi
Subyek
No Panggil
SKP 14AJ 2022
Copyright
Doi

Lampiran Berkas

LOADING LIST...



Informasi


DETAIL CANTUMAN


Kembali ke sebelumnya  XML Detail