ABSTRAK
Perbedaan Morfologi Sel Eritrosit dan Sel Leukosit Metode Romanowsky
Menggunakan Buffer Fosfat pH 6,8 dan Air Minum Dalam Kemasan
Peneliti : Dita Marlia Andini
Pembimbing : H. Ahmad Muhlisin; Erfan Roebiakto
Metode pewarnaan Sediaan Apusan Darah Tipis (SADT) yang dianjurkan
oleh The Internasional Council For Standardization in Haematology (ICSH)
salah satunya adalah Pewarnaan Romanowsky. Larutan pengencer yang digunakan
dalam pewarnaan Romanowsky adalah buffer fosfat. Buffer sebagai larutan
pengencer Romanowsky harus diperhatikan ketepatan Power of Hydrogen (pH)
untuk hasil pewarnaan yang baik. Larutan buffer fosfat pH 6,8 sulit didapat untuk
rumah sakit atau puskesmas yang jauh dipelosok dan harganya cukup mahal,
Sehingga sebagai alternatif air minum dalam kemasan bisa digunakan sebagai
larutan pengencer yang lebih murah dan mudah untuk diperoleh. Bertujuan untuk
mengetahui perbedaan morfologi sel eritrosit dan sel leukosit Metode
Romanowsky menggunakan Buffer Fosfat pH 6,8 dan Air Minum Dalam
Kemasan. Jenis penelitian observasional laboratorium dengan rancangan
comparative study dengan 6 jenis air minum dalam kemasan dan 3 level darah
kontrol yaitu high, normal, dan low. Dengan 5 kali pengulangan dalam satu merek
air minum dalam kemasan. Hasil penelitian morfologi sel eritrosit dan sel leukosit
pada darah kontrol high, normal dan low menggunakan buffer fosfat pH 6,8 dan
air minum dalam kemasan merek B, C, D dan F memiliki hasil pewarnaan yang
baik sedangakan air minum dalam kemasan E dan G memiliki hasil pewarnaan
yang tidak baik. Berdasarkan uji Wilcoxon morfologi sel eritrosit dan sel leukosit
didapatkan nilai sig >0,05 untuk air minum dalam kemasan B, C, D dan F
terhadap buffer fosfat (A) menunjukkan tidak ada perbedaan bermakna.
Disimpulkan bahwa air minum dalam kemasan dapat digunakan sebagai
pengencer dalam pewarnaan sediaan apusan darah tipis.
Kata Kunci : Morfologi Sel Eritrosit, Morfologi Sel Leukosit, Buffer Fosfat, Air
Minum Dalam Kemasan
ABSTRACT
Differences in the Morphology of Erythrocyte and Leukocyte Cells
Romanowsky Method Using Phosphate Buffer pH 6.8 and Bottled Drinking
Water
Author : Dita Marlia Andini
Supervisor : H. Ahmad Muhlisin; Erfan Roebiakto
One of the staining methods recommended by The International Council for
Standardization in Haematology (ICSH) is the Romanowsky stain. The diluent
used in Romanowsky's stain is phosphate buffer. Buffer as a Romanowsky diluent
must be considered for the accuracy of Power of Hydrogen (pH) for good staining
results. Phosphate buffer solution pH 6.8 is difficult to obtain for hospitals or
health centers that are far away and the price is quite expensive, so as an
alternative to bottled drinking water can be used as a diluent solution which is
cheaper and easier to obtain. Aims to determine the morphological differences
between erythrocytes and leukocytes. Romanowsky's method uses Phosphate
Buffer pH 6.8 and Bottled Drinking Water. This type of research is an
observational laboratory with a comparative study design with 6 types of bottled
drinking water and 3 control blood levels, namely high, normal, and low. With 5
repetitions in one brand of bottled drinking water. The results of the research on
morphology of erythrocyte cells and leukocyte cells in high, normal and low
control blood using phosphate buffer pH 6.8 and drinking water in brands B, C, D
and F good staining results, while drinking water in packages E and G had good
staining results. poor staining. Based on the Wilcoxon test, the morphology of
erythrocyte and leukocyte cells obtained sig values > 0.05 for drinking water in
packages B, C, D and F against phosphate buffer (A) which showed no significant
difference. It was concluded that bottled drinking water can be used as a diluent in
staining thin blood smears.
Keywords: Erythrocyte Cell Morphology, Leukocyte Cell Morphology,
Phosphate Buffer, Bottled Drinking Water


Detail Information

Item Type
Penulis
Dita Marlia Andini - Personal Name
H. Ahmad Muhlisin, M.Kes - Personal Name
Erfan Roebiakto, S.KM.,MS - Personal Name
Neni Oktiyani, M.Sc - Personal Name
Student ID
Dosen Pembimbing
Penguji
Kode Prodi PDDIKTI
Edisi
Departement
Kontributor
Bahasa
Indonesia
Penerbit Jurusan Analis Kesehatan : Banjarbaru.,
Edisi
Subyek
No Panggil
032/SKP-ANK-2022
Copyright
Doi

Lampiran Berkas

LOADING LIST...



Informasi


DETAIL CANTUMAN


Kembali ke sebelumnya  XML Detail