PENGOLAHAN AIR LIMBAH DOMESTIK PADA MES KARYAWAN INDUSTRI SEMEN DI PT. X

Detail Cantuman

CD room

PENGOLAHAN AIR LIMBAH DOMESTIK PADA MES KARYAWAN INDUSTRI SEMEN DI PT. X

XML

viii
KEMENTERIAN KESEHATAN REPUBLIK INDONESIA
POLITEKNIK KESEHATAN BANJARMASIN
PROGRAM STUDI SANITASI
PROGRAM DIPLOMA III
JURUSAN KESEHATAN LINGKUNGAN
TAHUN 2022
ABSTRAK
Karya Tulis Ilmiah
MOMOS GUNTUR PAMUNGKAS
“PENGOLAHAN AIR LIMBAH DOMESTIK PADA MES KARYAWAN
INDUSTRI SEMEN DI PT. X”
(Arifin S. KM, M.Kes dan Ir. Sulaiman Hamzani S.T., MT, IPM)
xiv + 39 Halaman ; 7 Tabel ; 2 Gambar ; 10 Lampiran
Semen merupakan komponen utama dalam pembangunan infrastruktur
seperti gedung, jalan tol, pelabuhan, bandara, jembatan dan berbagai infrastruktur
lain. Seperti halnya dengan industri lain, industri semen berpotensi untuk
menghasilkan limbah. Sumber limbah domestik di lingkungan industri dihasilkan
dari kegiatan karyawan berupa penggunaan kamar mandi, laundry dan kantin.
Kandungan organik pada limbah domestik masih menjadi masalah penting yang
mengakibatkan penurunan kualitas air sungai. Tujuan dari penelitian ini adalah
diketahuinya kualitas parameter TSS, pH, BOD, dan COD pada Effluent air limbah
domestik Pada mes Karyawan di PT. X.
Jenis Penelitian ini bersifat deskriptif, yaitu mendeskripsikan tentang
pengolahan air limbah domestik pada mes karyawan industri semen di PT. X.
desain penelitian bersifat Observasional, yaitu suatu prosedur yang terencana,
antara lain dengan melihat, mendengar, serta mencatat jumlah dan taraf aktivitas
atau situasi tertentu yang ada hubungannya dengan masalah yang diteliti, dan
metode pengambilan sampel dengan composite sampling, yaitu campuran sampel
yang diperoleh dari satu titik pada lokasi yang sama dengan waktu yang berbedabeda.
populasi yaitu air limbah yang keluar (Effluent) dari proses pengolahan air
limbah di PT. X. analisa deskriptif dengan memperhatikan hasil dengan standar
persyaratan baku mutu air limbah domestik sesuai dengan Permen LHK No.
P.68/2016.
Hasil penelitian menunjukan nilai TSS 2,1 mg/L nilai pH 7,7 nilai BOD 7,4
mg/L dan COD 14,4mg/L nilai tersebut sudah memenuhi baku mutu sesuai dengan
yang diterapkan yakni untuk parameter TSS 30 mg/L, pH 6 - 9, BOD 30 mg/L dan
COD 100 mg/L.
Upaya yang dilakukan untuk mempertahankan fungsi IPAL adalah
pemeliharaan secara berkala agar kualitas air limbah domestik tidak melebihi baku
mutu.
Kata Kunci : IPAL, Air Limbah Domestik, Industri, Kualitas Effluent
Kepustakaan : 19 (2006 - 2020)
ix
MINISTRY OF HEALTH THE REPUBLIC INDONESIA
HEALTH POLYTECHNIC BANJARMASIN
SANITATION STUDY PROGRAM
DIPLOMA THREE PROGRAM
ENVIRONMENTAL HEALTH
YEAR 2022
ABSTRACT
Scientific Papers
MOMOS GUNTUR PAMUNGKAS
“DOMESTIC WASTEWATER TREATMENT ON MES FOR CEMENT
INDUSTRY EMPLOYEES AT PT. X"
(Arifin S. KM, M.Kes and Ir. Sulaiman Hamzani S.T., MT, IPM)
xiv + 39 Pages ; 7 Tables ; 2 Image ; 10 Attachments
Cement is a major component in infrastructure development such as
buildings, toll roads, ports, airports, bridges and various other infrastructures. As
with other industries, the cement industry has the potential to generate waste.
Domestic waste sources in the industrial environment are generated from employee
activities in the form of using bathrooms, laundry and canteens. Organic content in
domestic waste is still an important problem that causes a decrease in river water
quality. The purpose of this study was to determine the quality of the parameters of
TSS, pH, BOD, and COD in domestic wastewater effluent at the employee mes at
PT. X.
This type of research is descriptive, which describes the treatment of domestic
wastewater at the cement industry employees at PT. X. The research design is
Observational, which is a planned procedure, among others by seeing, hearing, and
noting the number and level of activities or certain situations that have to do with
the problem being studied, and the sampling method using composite sampling,
which is a mixture of samples obtained from one point at the same location at
different times. population, namely the wastewater that comes out (Effluent) from
the wastewater treatment process at PT. X. descriptive analysis by taking into
account the results with the standard requirements for the quality of domestic
wastewater in accordance with the Minister of Environment and Forestry No.
P.68/2016.
The results showed that the TSS value was 2.1 mg/L, the pH value was 7.7,
the BOD value was 7.4 mg/L and the COD value was 14.4 mg/L. These values
already met the quality standard in accordance with the applied parameters, namely
for the TSS parameter of 30 mg/L, pH 6 - 9, BOD 30 mg/L and COD 100 mg/L.
Efforts made to maintain the function of the WWTP are periodic maintenance
so that the quality of domestic wastewater does not exceed the quality standard.
Keywords: WWTP, Domestic Wastewater, Industry, Effluent Quality
Literature : 19 (2006 - 2020)


Detail Information

Item Type
Penulis
Student ID
Dosen Pembimbing
Penguji
Kode Prodi PDDIKTI
Edisi
Departement
Kontributor
Bahasa
Indonesia
Penerbit Jurusan kesehatan lingkungan : Banjarbaru.,
Edisi
Subyek
No Panggil
044/KTI-KL/2022
Copyright
Doi

Lampiran Berkas

LOADING LIST...



Informasi


DETAIL CANTUMAN


Kembali ke sebelumnya  XML Detail