Kualitas Limbah Cair Pada IPAL Puskesmas X Ditinjau Dari Parameter pH, BOD, dan COD

Detail Cantuman

CD-ROM

Kualitas Limbah Cair Pada IPAL Puskesmas X Ditinjau Dari Parameter pH, BOD, dan COD

XML

KEMENTERIAN KESEHATAN REPUBLIK INDONESIA
POLITEKNIK KESEHATAN BANJARMASIN
PROGRAM STUDI SANITASI
PROGRAM DIPLOMA TIGA
KESEHATAN LINGKUNGAN
TAHUN 2022


ABSTRAK


Karya Tulis Ilmiah
TARANIA MEGA LESTARI
“KUALITAS LIMBAH CAIR PADA IPAL PUSKESMAS X DITINJAU DARI PARAMETER pH, BOD, DAN COD”
(Dr. H. Juanda, S.KM., M.Kes dan Syarifudin A, S.KM., M.S.)
xv + 49 halaman + 8 tabel + 6 gambar + 13 lampiran

Puskesmas menjadi tempat berkumpulnya orang sakit dan sehat sehingga berpotensi menjadi tempat penularan penyakit dan pencemaran lingkungan. Puskesmas X menghasilkan limbah cair yang diolah dengan sistem biofilter. Effluent dibuang ke lahan terbuka sehingga dapat berpotensi menyebabkan pencemaran pada air tanah. Tujuan dari penelitian ini untuk mengetahui tahapan pengolahan, spesifikasi IPAL, sumber, debit, dan kualitas effluent limbah cair.
Penelitian ini bersifat deskriptif dengan desain penelitian observasional dan metode pengambilan sampel grab sampling. Populasi dalam penelitian ini yaitu semua sistem pengolahan limbah cair yang dihasilkan dari aktivitas di Puskesmas X. Analisa deskriptif dengan memperhatikan hasil menurut Peraturan Menteri Lingkungan Hidup Indonesia Nomor 5 Tahun 2014 tentang Baku Mutu Air Limbah Bagi Usaha dan/atau Kegiatan Fasilitas Pelayanan Kesehatan.
Hasil penelitian menunjukkan sumber air limbah yang dihasilkan berupa limbah klinis dan non klinis. Spesifikasi IPAL dengan kapasitas 10-15 bed. Debit air limbah dari perhitungan yaitu 0,0175 L/detik. Proses pengolahan air limbah terdiri dari bak pengumpul/ bak kontrol, equalisasi, unit biofilter, dan bak klorinasi/bak indikator. Kualitas effluent pH 9,3; BOD 8,7 mg/L; COD 48,6 mg/L.
Tidak memenuhi syarat hasil pemeriksaan pH. Upaya yang dapat dilakukan untuk mengoptimalkan kinerja pengolahan air limbah dengan melakukan perawatan dan pemantauan secara periodik, dan pemberian dosis kaporit disesuaikan dengan air limbah yang dihasilkan dari pengolahan IPAL.



Kata Kunci : IPAL, Air Limbah Puskesmas, Kualitas Effluent
Kepustakaan : 37 (2003 – 2020)


MINISTRY OF HEALTH REPUBLIC INDONESIA
HEALTH POLYTECHNIC BANJARMASIN
SANITATION STUDY PROGRAM
DIPLOMA THREE PROGRAM
ENVIRONMENTAL HEALTH
YEAR 2022

ABSTRACT

Scientific Paper
TARANIA MEGA LESTARI
“QUALITY WASTEWATER IPAL AT X PUBLIC HEALTH CENTER PERFOMANCE WHICH OBSERVED FROM pH, BOD, AND COD”
(Dr. H. Juanda, S.KM., M.Kes and Syarifudin A, S.KM., M.S.)
xv + 49 pages + 8 tables + 6 pictures + 13 attachments

The Puskesmas is a gathering place for sick and healthy people so that it has the potential to become a place for disease transmission and environmental pollution. Puskesmas X produces liquid waste which is treated with a biofilter system. Effluent is discharged into open land so that it can potentially cause contamination of ground water. The purpose of this study was to determine the processing stages, IPAL specifications, source, discharge, and effluent quality of liquid waste.
This research is descriptive with an observational research design and grab sampling method. The population in this study are all wastewater treatment systems generated from activities at Puskesmas X. Descriptive analysis with attention to the results according to the Regulation of the Minister of the Environment of Indonesia Number 5 of 2014 concerning Wastewater Quality Standards for Business and/or Activities of Health Service Facilities.
The results showed that the sources of wastewater produced were clinical and non-clinical waste. IPAL specifications with a capacity of 10-15 beds. The wastewater discharge from the calculation is 0.0175 L/second. The wastewater treatment process consists of a collection tank/control tank, equalization, biofilter unit, and a chlorination tank/indicator tank. Effluent quality pH 9.3; BOD 8.7 mg/L; COD 48.6 mg/L.
Does not meet the requirements of the pH test results. Efforts can be made to optimize the performance of wastewater treatment by carrying out periodic maintenance and monitoring, and the administration of chlorine dosage adjusted to the wastewater generated from the IPAL treatment.


Key words : IPAL, Puskesmas Wastewater, Effluent Quality
Literature : 37 (2003 – 2020)


Detail Information

Item Type
Penulis
Tarania Mega Lestari - Personal Name
Dr. H. Juanda, S.KM., M.Kes - Personal Name
Syarifudin A, S.KM., M.S. - Personal Name
Student ID
Dosen Pembimbing
Penguji
Kode Prodi PDDIKTI
Edisi
Departement
Kontributor
Bahasa
Indonesia
Penerbit Jurusan kesehatan lingkungan : Banjarbaru.,
Edisi
Subyek
No Panggil
086/KTI-KL-2022
Copyright
Doi

Lampiran Berkas

LOADING LIST...



Informasi


DETAIL CANTUMAN


Kembali ke sebelumnya  XML Detail