GAMBARAN KUALITAS MIKROBA UDARA SEBELUM DAN SESUDAH DESINFEKSI DI RUANG ICU RSUD ULIN BANJARAMSIN

Detail Cantuman

CD-ROM

GAMBARAN KUALITAS MIKROBA UDARA SEBELUM DAN SESUDAH DESINFEKSI DI RUANG ICU RSUD ULIN BANJARAMSIN

XML

KEMENKES REPUBLIK INDONESIA
POLITEKNIK KESEHATAN BANJARMASIN
PROGRAM STUDI SANITASI
PROGRAM DIPLOMA TIGA
KESEHATAN LINGKUNGAN
TAHUN 2022

ABSTRAK
Karya Tulis Ilmiah

ALIKA WULANDARI SURANTO
GAMBARAN KUALITAS MIKROBA UDARA SEBELUM DAN SESUDAH DESINFEKSI DI RUANG ICU RSUD ULIN BANJARMASIN TAHUN 2022
(1) Zulfikar Ali As, S.KM., M.T, (2) H. M. Pahruddin, S.KM., M.KL
xiii+39 halaman; 4 tabel; 4 gambar; 10 lampiran

Udara bukan merupakan habitat untuk mikroorganisme, sel-sel mikroorganisme yang berada dalam udara sebagai kontaminan bersama debu dan percikan ludah atau air yang kemudian terbawa oleh hembusan angin ke udara. Tingkat pencemaran udara di dalam ruang ICU oleh mikroorganisme disebabkan oleh beberapa faktor seperti laju ventilasi, padatnya orang dan aktivitas staf yang melakukan kegiatan di ruangan tersebut. Mikroorganisme kemungkinan berasal dari percikan hidung dan mulut saat bersin, batuk maupun saat berbicara. Tujuan penelitian meliputi suhu, kelembaban serta angka kuman sebelum dan sesudah proses desinfeksi. Penelitian ini bersifat deskriptif dengan desain observasional. Populasi adalah udara dalam ruang ICU, karena hanya ada 1 ruang ICU maka sampel penelitian adalah populasi dari penelitian. Sampel pemeriksaan angka kuman udara diambil sebanyak 4 sampel dengan 2 sampel sebelum dan 2 sampel sesudah desinfeksi. Hasil pemeriksaan sampel angka kuman udara dilakukan pada laboratorium diketahui bahwa jumlah angka kuman sebelum dan sesudah desinfeksi berada diantara 150-487,5 CFU/m³. Kemudian hasil pengukuran suhu juga melebihi standar pada baku mutu yaitu berkisar antara 23,5°C-28,5°C dengan kelembaban antara 61%-68%. Angka kuman udara yang tinggi dapat menghasilkan bakteri atau mikroba di udara dan dapat menyebabkan infeksi nosokomial. Ada banyak hal yang bisa dilakukan untuk pengendalian angka kuman di udara, salah satunya dengan cara desinfeksi ruangan menggunakan dry mist. Penelitian ini memiliki kekurangan karena hanya dilakukan selama 2 kali saja sehingga dapat dikatakan dalam waktu yang singkat. Maka bagi peneliti yang ingin melakukan penelitian ini agar menambah waktu sampling, jumlah titik sampling dan dalam kondisi pengambilan yang berbeda-beda untuk mendapatkan hasil yang sempurna.


Kata Kunci : Angka Kuman Udara, Rumah Sakit, Ruang ICU, Desinfeksi
Kepustakaan : 29 (2004-2021)



MINISTRY OF HEALTH REPUBLIC INDONESIA
HEALTH POLYTECHNIC BANJARMASIN
SANITATION STUDY PROGRAM
DIPLOMA THREE PROGRAM
ENVIRONMENTAL HEALTH
YEAR 2022

ABSTRACK
SCIENTIFIC PAPERS

ALIKA WULANDARI SURANTO
DESCRIPTION OF AIR MICROBIAL QUALITY BEFORE AND AFTER DISINFECTION IN ICU ROOM ULIN HOSPITAL BANJARMASIN, 2022
(1) Zulfikar Ali As, S.KM., M.T, (2) H. M. Pahruddin, S.KM., M.KL
xiii+39 pages; 4 tables; 4 pictures; 10 attachments

Air is not a habitat for microorganisms, microorganism cells that are in the air as contaminants with dust and splashes of saliva or water which are then carried away by wind gusts into the air. The level of air pollution in the ICU room by microorganisms is caused by several factors such as the ventilation rate, the density of people and the activities of the staff who carry out activities in the room. Microorganisms may come from the splashes of the nose and mouth when sneezing, coughing or when talking. The research objectives include temperature, humidity and germ numbers before and after the disinfection process. This research is descriptive with an observational design. The population is the air in the ICU room, because there is only 1 ICU room, the research sample is the population of the study. 4 samples of air germ number examination were taken with 2 samples before and 2 samples after disinfection. The results of the examination of airborne germ numbers in the laboratory showed that the number of germs before and after disinfection was between 150-487.5 CFU/m³. Then the results of temperature measurements also exceed the standard on the quality standard, which ranges between 23.5°C-28.5°C with humidity between 61%-68%. High air germ numbers can produce bacteria or microbes in the air and can cause nosocomial infections. There are many things that can be done to control the number of germs in the air, one of which is by disinfecting the room using dry mist. This research has drawbacks because it was only conducted for 2 times so that it can be said in a short time. So for researchers who want to do this research in order to increase the sampling time, the number of sampling points and in different taking conditions to get perfect results.

Keywords : Air germ number, Hospital, ICU Room, Disinfektion2
Literature : 29 (2004-2021)


Detail Information

Item Type
Penulis
ALIKA WULANDARI SURANTO - Personal Name
ZULFIKAR ALI As, S.KM.M.T - Personal Name
Dr. JUNAIDI, S.KM.MS - Personal Name
H. M. Pahruddin, S.KM., M.KL - Personal Name
Student ID
Dosen Pembimbing
Penguji
Kode Prodi PDDIKTI
Edisi
Publish
Departement
Kontributor
Bahasa
Indonesia
Penerbit Jurusan kesehatan lingkungan : Banjarbaru.,
Edisi
Publish
Subyek
No Panggil
017/KTI-KL/2022
Copyright
Doi

Lampiran Berkas

LOADING LIST...



Informasi


DETAIL CANTUMAN


Kembali ke sebelumnya  XML Detail