PENURUNAN KADAR BOD DAN COD LIMBAH CAIR DENGAN SISTEM COARSE SCREEN, SEDIMENTASI, BIOFILTER ANAEROB-AEROB (Studi Kasus di Rumah Potong Hewan Kabupaten Banjar)

Detail Cantuman

CD-ROM

PENURUNAN KADAR BOD DAN COD LIMBAH CAIR DENGAN SISTEM COARSE SCREEN, SEDIMENTASI, BIOFILTER ANAEROB-AEROB (Studi Kasus di Rumah Potong Hewan Kabupaten Banjar)

XML

KEMENTERIAN KESEHATAN REPUBLIK INDONESIA
POLITEKNIK KESEHATAN BANJARMASIN
JURUSAN KESEHATAN LINGKUNGAN
PROGRAM STUDI SANITASI LINGKUNGAN
PROGRAM SARJANA TERAPAN
TAHUN 2020

ABSTRAK
SKRIPSI

SITI RABIATUL ADAWIAH
PENURUNAN KADAR BOD DAN COD LIMBAH CAIR DENGAN SISTEM COARSE SCREEN, SEDIMENTASI, BIOFILTER ANAEROB-AEROB (Studi Kasus di Rumah Potong Hewan Kabupaten Banjar)
(Syarifudin A, S.KM., MS. dan Munawar Raharja, S.Si., M.PH.)
Xiv + 60 Halaman : 23 tabel ; 7 Gambar ; 6 Lampiran

Salah satu alternatif pengolahan air limbah yang sesuai untuk rumah potong hewan yaitu dengan memanfaatkan teknologi gabungan dari fisika dan biologi yaitu kombinasi dari biofilter anaerob dan biofilter aerob yang di dalamnya menggunakan sistem coarse screen, sedimentasi biofilter anaerob dan aerob, sehingga dari sistem pengolahan tersebut dapat menurunkan kadar BOD dan COD pada limbah rumah potong hewan. Penelitian ini bertujuan untuk mengetahui perbedaan antar variasi waktu tinggal bak biofilter aerob dalam menurunkan kadar BOD dan COD limbah cair rumah potong hewan.
Jenis penelitian yang digunakan bersifat eksperimental, yaitu melakukan percobaan dengan membedakan waktu tinggal pada bak biofilter aerob, desain penelitian yang digunakan yaitu One Group Pretest-Posttes Design. Analisis data menggunakan uji statistik One Way Analisys of varience dengan = 0,05.
Hasil analisis kandungan kadar BOD dan COD mengalami penurunan setelah dilakukan perlakuan disetiap waktu tinggal, dengan waktu tinggal 6 jam pada bak biofilter aerob sudah mampu menurunkan kadar BOD sebesar 70 persen dan COD sebesar 66,2persen. Sedangkan dengan waktu tinggal 24 jam mampu menurunkan kadar BOD hingga 80persendan kadar COD hingga 72 persen. Berdasarkan hasil uji One Way Analisys Of Variance bahwa ada perbedaan yang signifikan dari semua variasi waktu tinggal tersebut karena nilai p (0,000) < (0,05).
Disarankan untuk peneliti selanjutnya agar melakukan penelitian menggunakan media yang porinya lebih besar misalnya seperti menggunakan bioball atau potongan pipa PVC dengan waktu tinggal yang lebih lama.

Kata Kunci : Biofilter Anaerob-Aerob, Limbah rumah potong hewan, BOD,
COD
Kepustakaan : 30 (1967- 2019) 
MINISTRY HEALTH OF REPUBLIC INDONESIA
HEALTH POLYTECHNIC OF BANJARMASIN
APPLIED UNDERGRADUATE ENVIRONMENTAL SANITATION STUDY PROGRAM
ENVIRONMENTAL HEALTH
YEAR 2020

ABSTRACT

ESSAY
SITI RABIATUL ADAWIAH
DECREASED BOD AND COD LEVELS OF LIQUID WASTE WITH COARSE SCREEN SYSTEM, SEDIMENTATION, ANAEROB-AEROB BIOFILTER (Case study at Slaughterhouse in Banjar Regency)
(Syarifudin A, S.KM., MS. dan Munawar Raharja, S.Si., M.PH.)
Xiv + 60 Pages : 23 tables ; 7 Figures ; 6 Appendices

One alternative wastewater treatment suitable for slaughterhouses is by utilizing the combined technology of physics and biology namely the combination of anaerobic biofilters and aerobic biofilters in the coarse screen system, anaerobic biofilters sedimentation and Aerobic biofilters so that from the processing system can lower the BOD and COD levels on the household waste of animal. This research aims to know the difference between the time variation of the body of aerobic biofilters in lowering the BOD and COD levels of liquid waste housing.
The type of research used experimental, The experiment by distinguishing the time of stay on aerobic biofilters tubs, The research design used One Group Pretest-Posttest Design. Data analysis using statistical test One Way Analysis of variance with = 0.05.
The result showed that the content BOD and COD decreased after treatment at every time of stay, with a 6-hour stay in the aerobic biofilters body is able to lower the BOD rate by 70 percent and COD by 66,2percent. While the 24-hour stay is able to lower the BOD rate up to 80 percent and COD levels up to 72 percent. Based on the test results One Way Analysis Of Variance that there is a significant difference from all variations of the time of the stay because of the value p (0,000) < (0,05).
It is advisable for future researchers to conduct research using media with larger portions such as using Bio ball or PVC pipe pieces with longer stay times.

Keywords : Anaerob-Aerob biofilter, animal waste slaughterhouse, BOD
and COD
literature : 30 ( 1967-2019)


Detail Information

Item Type
Penulis
SITI RABIATUL ADAWIAH - Personal Name
Syarifudin A., S.KM, MS - Personal Name
Munawar Raharja, S.Si, M.PH - Personal Name
Student ID
Dosen Pembimbing
Penguji
Kode Prodi PDDIKTI
Edisi
Departement
Kontributor
Bahasa
Indonesia
Penerbit Jurusan kesehatan lingkungan : Banjarbaru.,
Edisi
Subyek
No Panggil
KL.11/SKP.2020
Copyright
Doi

Lampiran Berkas

LOADING LIST...



Informasi


DETAIL CANTUMAN


Kembali ke sebelumnya  XML Detail