<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" ID="2522">
<titleInfo>
<title><![CDATA[Ketepatan Kadar Kolesterol Total Metode POCT (Point Of Care Test) Dibanding  Dengan Metode CHOD-PAP (Cholesterol Oksidase Para Amino Phenazone) Pada  Pasien Lansia Di UPT Puskesmas Sungai Turak Kabupaten Hulu Sungai Utara]]></title>
</titleInfo>
<name type="Personal Name" authority="">
<namePart>Dra. Anny Thuraidah, Apt.,MS.</namePart>
<role><roleTerm type="text">Dosen Pembimbing 2</roleTerm></role>
</name>
<name type="Personal Name" authority="">
<namePart>Jujuk Anton Cahyono, M.Sc</namePart>
<role><roleTerm type="text">Dosen Pembimbing 1</roleTerm></role>
</name>
<name type="Personal Name" authority="">
<namePart>Netty Agustina</namePart>
<role><roleTerm type="text">Pengarang</roleTerm></role>
</name>
<name type="Personal Name" authority="">
<namePart>Dra. Ratih Dewi Dwiyanti, M.Kes</namePart>
<role><roleTerm type="text">Ketua Penguji</roleTerm></role>
</name>
<typeOfResource manuscript="yes" collection="yes"><![CDATA[mixed material]]></typeOfResource>
<genre authority="marcgt"><![CDATA[bibliography]]></genre>
<originInfo>
<place><placeTerm type="text"><![CDATA[Banjarbaru]]></placeTerm></place>
<publisher><![CDATA[Jurusan Analis Kesehatan ]]></publisher>
<dateIssued><![CDATA[2022]]></dateIssued>
<issuance><![CDATA[monographic]]></issuance>
<edition><![CDATA[0]]></edition>
</originInfo>
<language>
<languageTerm type="code"><![CDATA[id]]></languageTerm>
<languageTerm type="text"><![CDATA[Indonesia]]></languageTerm>
</language>
<physicalDescription>
<form authority="gmd"><![CDATA[CD room]]></form>
<extent><![CDATA[]]></extent>
</physicalDescription>
<note>ABSTRAK
Ketepatan Kadar Kolesterol Total Metode POCT (Point Of Care Test) Dibanding 
Dengan Metode CHOD-PAP (Cholesterol Oksidase Para Amino Phenazone) Pada 
Pasien Lansia Di UPT Puskesmas Sungai Turak Kabupaten Hulu Sungai Utara
Peneliti : Netty Agustina
Pembimbing : Jujuk Anton Cahyono, Anny Thuraidah
Peningkatan kadar Kolesterol terjadi pada Usia Lanjut, hal itu dikarenakan 
faktor usia yang semakin lama badan akan semakin malas digerakkan, sehingga 
kolesterol meningkat di dalam darah. Pemeriksaan kadar kolesterol ada beberapa 
metode, diantaranya adalah metode CHOD PAP dan POCT. Tidak jarang masyarakat 
mendapati hasil pemeriksaan kolesterol yang berbeda antara hasil metode CHODPAP, POCT Nesco dan Autocheck. Penelitian ini bertujuan untuk mengetahui 
ketepatan kadar kolesterol metode POCT dibanding dengan CHOD-PAP dengan jenis 
penelitian survei analitik. dan rancangan cross sectional. Populasi penelitian ini adalah 
seluruh Lansia yang melakukan pemeriksaan kolesterol di UPT Puskesmas Sungai 
Turak pada bulan Juli Tahun 2022. Teknik sampling adalah Accidental Sampling, 
jumlah sampel 35 orang. Hasil rerata POCT Autocheck 247,5 mg/dl, rerata POCT 
Nesco 224,9 mg/dl, sedangkan rerata CHOD-PAP 192,7 mg/dl. Hasil uji statistik 
Repeated Measure Anova didapatkan signifikansi = 0,000 < 0,005 yang artinya 
terdapat perbedaan bermakna kolesterol pada POCT Nesco, POCT Autocheck, dan 
CHOD-PAP. Bias POCT Nesco 17% dan POCT Autocheck 28%. Kesimpulannya
POCT Nesco memiliki nilai ketepatan lebih mendekati dibanding POCT Autocheck. 
Disarankan untuk menggunakan CHOD-PAP jika tidak ada dapat menggunakan
POCT Nesco, dapat melakukan penelitian disertai bahan kontrol agar presisi dan 
akurasi terlihat.
Kata Kunci : Kolesterol, CHOD-PAP, POCT, Lansia
ABSTRACT
Accuracy of Total Cholesterol Levels POCT Method (Point Of Care Test) 
Compared With CHOD-PAP (Cholesterol Oxidase Para Amino Phenazone) 
Method in Elderly Patients At UPT Puskesmas Sungai Turak, Hulu Sungai 
Utara Regency
Author: Netty Agustina
Advisor : Jujuk Anton Cahyono, Anny Thuraidah
Increased cholesterol levels occur in old age, this is due to the age factor, the 
longer the body will be lazy to move, so that cholesterol increases in the blood. There 
are several methods for examining cholesterol levels, including the CHOD PAP and 
POCT methods. It is not uncommon for people to find different cholesterol test 
results between the results of the CHOD-PAP, POCT Nesco and Autocheck methods. 
This study aims to determine the accuracy of cholesterol levels using the POCT 
method compared to CHOD-PAP with the type of analytical survey research. and 
cross sectional design. The population of this study were all elderly people who had 
their cholesterol checked at the UPT Puskesmas Sungai Turak in July 2022. The 
sampling technique was accidental sampling, the sample size was 35 people. The 
average POCT Autocheck result was 247.5 mg/dl, Nesco's POCT average was 224.9 
mg/dl, while the CHOD-PAP average was 192.7 mg/dl. The results of the Repeated 
Measure Anova statistical test obtained significance = 0.000 <0.005, which means 
that there is a significant difference in cholesterol in POCT Nesco, POCT Autocheck, 
and CHOD-PAP. Nesco's POCT bias is 17% and POCT Autocheck is 28%. In 
conclusion, POCT Nesco has a closer accuracy value than POCT Autocheck. It is 
recommended to use CHOD-PAP if not available, you can use POCT Nesco, you can 
do research with control materials so that precision and accuracy can be seen.
Keywords: Cholesterol, CHOD-PAP, POCT, Elderly</note>
<subject authority=""><topic><![CDATA[SKP AJ Tahun 2022]]></topic></subject>
<classification><![CDATA[SKP 25AJ 2022]]></classification><identifier type="isbn"><![CDATA[20231207]]></identifier><location>
<physicalLocation><![CDATA[Repository Poltekkes Kemenkes Banjarmasin]]></physicalLocation>
<shelfLocator><![CDATA[SKP 25AJ 2022]]></shelfLocator>
<holdingSimple>
<copyInformation>
<numerationAndChronology type="1"><![CDATA[SKP 25AJ 2022]]></numerationAndChronology>
<sublocation><![CDATA[Jurusan Analis Kesehatan (SKP AJ 2022)]]></sublocation>
<shelfLocator><![CDATA[SKP 25AJ 2022]]></shelfLocator>
</copyInformation>
</holdingSimple>
</location>
<slims:digitals>
<slims:digital_item id="2950" url="" path="/BAB I.pdf" mimetype="application/pdf"><![CDATA[Bab 1]]></slims:digital_item>
<slims:digital_item id="2951" url="" path="/BAB II.pdf" mimetype="application/pdf"><![CDATA[Bab 2]]></slims:digital_item>
</slims:digitals><recordInfo>
<recordIdentifier><![CDATA[2522]]></recordIdentifier>
<recordCreationDate encoding="w3cdtf"><![CDATA[2023-05-10 08:33:10]]></recordCreationDate>
<recordChangeDate encoding="w3cdtf"><![CDATA[2023-05-10 08:34:12]]></recordChangeDate>
<recordOrigin><![CDATA[machine generated]]></recordOrigin>
</recordInfo></mods></modsCollection>